If your Rinnai tankless is beeping and flashing a number like 11, 12, or 10, the controller is telling you which part of the system stopped it. A couple of those codes have a simple first check you can do yourself. Most of them don't, and a few mean you should stop using the heater until someone looks at it.
This is a code-by-code reference for Rinnai tankless water heaters. After Navien, Rinnai and Noritz are the brands we see most around Cabarrus, Rowan, and Iredell County, about evenly. Every meaning below comes from Rinnai's own manuals and troubleshooting guide. For each code you'll get what it means, what's safe for a homeowner to check, and when it's time to call a pro.
Write the code down or take a photo of the controller before you press anything. Whoever you call, that number is the first thing they'll ask for.
Then check the rating label on the side of the unit for the model number. Rinnai's codes are mostly shared across its line, but a few aren't:
If a code isn't in the table below, it's a technician code in Rinnai's guide. And if your Rinnai is one of the older non-condensing units and it's starting to throw codes often, it may be worth comparing a repair against the cost of a new tankless water heater installation before you put money into it.
Rinnai doesn't have one reset button that clears everything. What its manuals actually say:
We're fine with you trying one power cycle before you call us. Reset once. If the same code comes back right away, or comes back every few days, the heater is telling you something real. Resetting it again won't fix the cause.
You can also see the last nine codes your unit has thrown, which helps whoever services it. Turn the unit off, hold the On/Off button for two seconds, and press the Up arrow at the same time. Repeat the same steps to exit.
| Code | What Rinnai says it means | What you can safely check | Call a pro? |
|---|---|---|---|
| 03 | Power went out during a bath fill | Turn off hot taps, press On/Off twice | If it comes back |
| 05 | Bypass flow control | Power off and on, then run hot water | If it comes back |
| 10 | Air supply or exhaust blocked (or condensate trap full on condensing units) | Outside vent and intake clear; condensate line not kinked or frozen | If it comes back |
| 11 | No ignition | Gas valve to the heater open; other gas appliances working; propane tank not empty | If it comes back after one reset |
| 12 | Flame failure | Same as 11: gas on, propane in the tank | If it comes back |
| 14 | Overheat (heat exchanger or thermal fuse) | Nothing | Yes |
| 16 | Outgoing water too hot (safety shutdown) | Nothing | Yes |
| 19 | Electrical grounding fault | Nothing | Yes |
| 25 | Condensate pump (SENSEI accessory) | Pump plugged in and running; drain line not clogged or frozen | If it comes back |
| 32, 33, 38, 41, 51 | Temperature sensors | Nothing | Yes |
| 52 | Gas valve | Nothing | Yes |
| 54 | High exhaust temperature | Nothing outside the cabinet | Yes |
| 61 | Combustion fan | Nothing | Yes |
| 63 | Recirculation low flow | Recirculation valves open | If it comes back |
| 65 | Water flow control failed to close during bath fill | Turn the water off now | Yes, right away |
| 70, 71 | Circuit board or solenoid circuit | Nothing | Yes |
| 72 | Flame rod | Nothing | Yes |
| 79 | Water leak detected (older models) | Look for water under the unit | Yes |
| SS | Service Soon: flush reminder (SENSEI) | Nothing to fix; it's a maintenance reminder | Schedule a flush |
| LC (LC0 to LC9) | Scale buildup in the heat exchanger | Nothing to fix; it needs a flush | Schedule a flush soon |
| FF | Maintenance record, not a fault | Nothing | No |
The Rinnai codes we see most around here are 10, 11, and 12, so those come first.
Code 11 is the one people search for most, and it means the heater tried to light and couldn't. Rinnai's first checks are about gas: is it on at the heater, at the meter, or at the propane tank, and is the tank actually full?
What you can check: Make sure the gas valve on the line into the heater has its handle running in line with the pipe (open). See whether your range or furnace is working. If you're on propane, check the tank gauge. If the gas was just turned back on after work on the line, air in the line can cause a code 11 for a few tries. Then reset once.
When it's a pro call: If the gas is on and 11 keeps coming back, Rinnai's list moves into gas pressure, gas type, the igniter, the flame rod, and a blocked condensate line on condensing units. All of that is behind the cover. When we see a Rinnai code 11 around here, the most common cause is a dirty flame rod. You'll see videos and AI answers telling you to pull the cover and sand the flame rod yourself. Rinnai's own guide puts that work with a trained professional, and on a gas appliance that's where it belongs. If you smell gas, leave the house and call your gas utility first.
Code 12 means the burner lit and then lost its flame. Rinnai's checks are nearly the same as for 11: gas on, propane in the tank, correct gas type and pressure, and the flame rod wire connected.
What you can check: The same gas checks as code 11, then reset once.
When it's a pro call: If it repeats. A flame that lights and drops out points to gas pressure, the flame rod, or venting, and each of those is a service visit.
Code 10 means the heater isn't getting enough combustion air or can't push exhaust out. On condensing models like the SENSEI and RX, Rinnai adds one more cause: a full condensate trap.
What you can check: Go outside and look at the vent and intake. Leaves, a wasp or bird nest, snow, or a shrub that's grown over the termination can all do it. On a condensing unit, make sure the small condensate drain line isn't kinked, clogged, or frozen. Then reset once.
When it's a pro call: If the openings are clear and 10 comes back, or if any vent pipe looks cracked, separated, or melted. Venting on a gas appliance is a carbon monoxide safety issue, and Rinnai's checklist also includes vent length and the fan, which are installation questions. We go deeper on venting in our tankless venting guide.
Rinnai's own troubleshooting guide says code 14 "should be taken seriously." It means the heat exchanger got too hot, and the usual cause is scale building up inside it.
What you can check: Nothing inside the unit. Turn it off and call.
When it's a pro call: Always. On some models the overheat switch resets itself once it cools, but the thermal fuse behind code 14 is a one-time part and has to be replaced. The fix also has to deal with why it overheated, which usually means a flush and, on hard water, some kind of treatment.
Code 61 means the fan that pushes air through the burner isn't running right. Rinnai's checks are the fan's wiring, its resistance, and whether it spins freely, all inside the cabinet.
What you can check: Nothing past a single reset.
When it's a pro call: If it comes back. A failing fan is a part replacement.
This one only shows up on units set up for bath fill, but Rinnai's instructions are urgent: the water flow control failed to close. Turn the water off right away, stop using the bath fill feature, and call a pro.
These two are about scale, and they're the codes we'd most like Rinnai owners to understand.
SS ("Service Soon") is a reminder on SENSEI models. The installer sets how often it comes on: every six months, every year, or every two years, based on the water. It doesn't mean anything is broken yet. It means the heat exchanger is due for a flush.
LC codes (LC0 through LC9) show up on RX models and older units when scale has built up in the heat exchanger. LC is the only Rinnai code that lets the heater keep running for a while, which is why people ignore it. On newer units, pressing On/Off five times buys you about 70 hours, and then it locks out again. The number after LC counts how many times that's happened. An LC2 means someone has already pushed through it three times without flushing.
Here's the part that matters: Rinnai's warranty doesn't cover damage from scale buildup. Clearing an SS or LC code without flushing the unit is how a maintenance visit turns into a heat exchanger replacement.
Our recommendation is simple: flush a tankless once a year, whether your home is on city water in Concord, Kannapolis, or Salisbury or on a private well in Rowan or Iredell County. Don't wait for the SS or LC code to tell you.
Want to learn more about your options? Give us a call to chat with a friendly guide.

No code doesn't always mean nothing's wrong. The common causes are a hot water tap that isn't open far enough to trigger the burner (tankless units need a minimum flow to fire), a clogged inlet filter, a frozen unit after a cold snap, or a mixing valve somewhere in the house letting cold water cross into the hot line. Start by opening the tap all the way. If you have a recirculation system and only one fixture is slow to get hot, our hot water recirculation guide covers how those work.
Rinnai is direct about this. Its manual says some checks "should be performed by a trained and qualified professional" and that homeowners "should never attempt any action that they are not qualified to perform." A homeowner can safely:
Everything else goes to a pro: gas work, venting repairs, anything behind the front cover, and the heat exchanger flush if you're not set up for it. Rinnai's manual says the heater should be inspected once a year by a trained and qualified professional.
Rinnai's residential warranty covers the heat exchanger for 15 years (or 12,000 operating hours) on current models, other parts for 5 years, and labor for 1 year. It doesn't cover damage from improper maintenance, and Rinnai names scale buildup, freeze damage, and vent blockage specifically. It also says repairs have to be done by a qualified professional, and that changes to the unit can void the warranty.
So skipping flushes and resetting LC codes can cost you more than a service call. If your unit is still under warranty, have it looked at before you order parts online.
We'll be straight with you: when we install a new tankless, we usually put in a Navien. Our owner, Jonathan Johns, is a Navien Certified Service Specialist, and staying consistent on one brand is how we keep parts on hand and repairs quick. But plenty of homes around here already have a Rinnai, often put in by the builder, and we service all the major tankless brands, Rinnai included.
When you call us with a Rinnai code, the person who diagnoses it is the person who does the work. We'll read the code history, find the actual cause, and tell you what's wrong and what it costs before any work starts. If it turns out the unit is near the end of its life, we'll tell you that plainly too. Our service call is $94, and it's waived when you go ahead with the repair. After-hours visits (after 5 PM on weekdays, and on Saturdays) are $189. Full water heater and tankless pricing is on our pricing page.
Code 11 means no ignition: the heater tried to light and couldn't. Rinnai's first checks are that the gas is on at the heater, at the meter, or at the propane tank, and that the tank isn't empty. Air in the gas line after work on it can also cause it. Reset once. If 11 comes back, call a pro. Around here, the most common cause we find is a dirty flame rod, which is behind the cover.
For most codes, turn the unit off at the controller, wait about five seconds, and turn it back on. For code 03, turn off the hot taps and press On/Off twice. For the SS service reminder, press On/Off five times within five seconds. Reset once. If the same code comes back, the heater needs service.
LC means scale has built up in the heat exchanger and the unit needs to be flushed. On newer models, pressing On/Off five times lets it run for about 70 hours before it locks out again, and the number after LC counts how many times that's been done. Rinnai's warranty doesn't cover scale damage, so schedule the flush instead of clearing the code.
We recommend once a year, whether your home is on city water or a private well. Rinnai's manual also calls for a yearly inspection by a qualified professional. Don't wait for an SS or LC code: by the time scale trips a code, it's already built up inside the heat exchanger.
Code 10 means the heater's air supply or exhaust is blocked, or on condensing models, the condensate trap is full. Check that the outside vent and intake are clear of leaves, nests, or snow, and that the condensate line isn't kinked or frozen. If it comes back, have the venting checked.
A few have a safe first check: gas on for codes 11 and 12, the outside vent for code 10, and the condensate pump for code 25. Rinnai's manual says some checks should be done by a trained professional and that homeowners shouldn't attempt work they aren't qualified for. Gas, venting, and anything inside the cabinet belong to a pro.
The code meanings in this article come from Rinnai's own installation and operation manuals and its diagnostic code troubleshooting guide. Your model's manual is on Rinnai's product documentation page, and Rinnai's support line is 1-800-621-9419.
If your Rinnai is showing a code that keeps coming back, or you'd rather not guess, give us a call. We'll tell you straight what the code means on your unit and what it'll take to fix it. You can reach us at (704) 798-2659 or book online. You can also read more about our tankless water heater repair and maintenance service, or see our Navien and Noritz error code guides if you have one of those.

Jonathan Johns is the owner and lead plumber at Macaw Plumbing & Tankless, a family-owned plumbing company serving Salisbury, Mooresville, China Grove, and surrounding communities across Cabarrus, Rowan, and Iredell Counties. He holds NC State License #L.35944 (North Carolina P1 Unlimited Plumbers License) with Well Seal Certification and is a certified Navien Service Specialist.