(704) 798-2659

Noritz Error Codes, Code by Code

November 17, 2026

Reviewed & Published by:

Jon Johns

Image

If your Noritz tankless is showing a number like 11, 90, or 16 and the hot water just quit, the remote is telling you which part of the system shut it down. A few of those codes have a simple first check you can do yourself. Some can't be reset at all, and a couple mean the heater shouldn't run until someone looks at it.

After Navien, Noritz and Rinnai are the brands we see most around Cabarrus, Rowan, and Iredell County, about evenly. Builders and contractors put Noritz units in a lot of the newer homes here, so plenty of homeowners inherited one without ever choosing it. Earlier this year, a homeowner in Concord found us by asking ChatGPT what to do about their Noritz. This article is the answer we'd give anyone asking that question. Every code meaning below comes from Noritz's own manuals and Knowledge Base.

First, Write Down the Code and Find Your Model

Write the code down or take a photo of the remote before you press anything. It's the first thing anyone will ask for.

Then find the model number on the rating label on the side of the heater. Noritz codes aren't identical across its whole lineup, and that trips people up online:

  • Condensing "premix" models (EZ series like the EZ111DV, NRCR, and CDV) have their own code set, including the C1# scale reminder.
  • Older non-condensing and copper heat exchanger models (N-series like the N-0751M) use some codes the newer ones don't, like 14.
  • The NRCP982 shows codes with an "Er:" in front, and on that model 29 means something different than it does on other Noritz units.

If you search a code and the answer doesn't match what your heater is doing, check that the answer is for your model. And if your Noritz came with the house and it's getting up in years, it's worth knowing what a new tankless water heater installation involves before you put money into a big repair.

How to Reset a Noritz Tankless Water Heater

Noritz's reset is simple: turn the power off and back on. For most codes that means unplugging the heater (or switching off its breaker), waiting 20 to 30 seconds, and plugging it back in. For a code 11, Noritz also says closing and reopening the hot water faucet can be enough to retry.

We're fine with you trying one power cycle before you call us. Reset once. If the same code comes back right away, or comes back every few days, the heater is telling you something real.

And two codes can't be reset, no matter how many times you try: 14 and 908. More on those below.

Noritz Error Codes at a Glance

CodeWhat Noritz says it meansWhat you can safely checkCall a pro?
10Combustion abnormality, an early warning of 90 (premix models)Outside vent and intake clear; one resetIf it comes back
11Ignition failureGas valve to the heater open; other gas appliances working; propane not emptyIf it comes back after one reset
12Flame loss after lightingSame gas checks as 11, then one resetYes, if it repeats
14Thermal fuse tripped by a major overheatNothing. Can't be resetYes
16Outlet water temperature spiked too highOne reset (unplug for 20 seconds)Yes, if it comes back
20High limit switch trippedOne resetYes, if it comes back
29Condensate drain problem (condensing models)Drain line clear, sloped, not frozenIf it comes back
31, 32, 33Temperature sensorsNothingYes
45Water leak inside the cabinet (NRCP and some models)Look for water in the bottom of the unitYes
61Fan motorOne reset (wind gusts can trigger it once)Yes, if it repeats
63 (or 06)Recirculation problemReturn line and crossover valve filtersIf it comes back
65, 66Water flow servoNothingYes
71Gas valve circuitPlug into a different outlet; check any backup powerIf it comes back
72Flame sensed before ignitionNothingYes
73Circuit board settingUnplug for 30 secondsIf it comes back
90 (901, 903)Combustion abnormality: fuel and air mix offOutside vent and intake clear; condensate line not clogged or frozenYes, right away if it repeats
908Internal lock after repeated combustion faultsNothing. Can't be resetYes
91Wrong gas type or gas conversionNothing. Don't run the unitYes
92, 93Neutralizer near or at end of life (older condensing models)NothingSchedule service
760Remote isn't talking to the heaterRemote cord pushed in all the wayIf it comes back
C1#Scale buildup reminder: time to flushNothing to fix; it needs a flushSchedule a flush

The Common Codes, One by One

The Noritz codes we see most around here are 10, 11, and 12, so those come first.

Code 11: Ignition Failure

Code 11 is the Noritz code people search for most. It means the heater saw the demand for hot water but couldn't light, either because it didn't get a spark, didn't get enough gas, or the flame rod didn't see the flame.

What you can check: Make sure the gas valve on the line into the heater is open (handle in line with the pipe). Check whether your range or furnace is working, and if you're on propane, check the tank. Then close and reopen the hot water faucet, or power the heater off and back on.

When it's a pro call: If the gas is on and 11 keeps coming back. When we see a Noritz code 11 around here, the most common cause is a dirty flame rod. Getting to it means opening the cabinet, and gas pressure and spark testing take a manometer, so all of that belongs to a licensed plumber. If you smell gas, leave the house and call your gas utility first.

Code 12: Flame Loss

Code 12 means the burner lit and then lost its flame. It's a close cousin of code 11, and the causes overlap: the gas supply, the flame rod, and the venting.

What you can check: The same gas checks as code 11, then one reset.

When it's a pro call: If it repeats. A flame that lights and then drops out is a service visit, not something to keep resetting.

Codes 10 and 90: Combustion Abnormality

Code 10 is one of the codes we see most, and on newer premix models it's often the early warning before a 90. Code 90 means the mix of fuel and air isn't right. The heater either can't move air in and exhaust out, or it can't reach its set temperature. Noritz says that on a new install it's usually gas pressure, venting, or a setting, and on an older unit it's usually dirt and lint that built up from missed maintenance. You may also see 901 or 903, which point the same direction.

What you can check: Go outside and look at the vent and air intake. Leaves, nests, snow, or a shrub grown over the opening can all do it. Noritz specifically mentions sudden weather, like a storm, as a trigger. On a condensing unit, make sure the condensate drain line isn't clogged or frozen.

When it's a pro call: Noritz's own advice on a 90 is to contact a contractor right away. And if a 90 keeps getting reset, the heater can lock itself out with a 908, which can't be cleared from the remote at all. We cover what good venting looks like in our tankless venting guide.

Code 14: Thermal Fuse (Can't Be Reset)

Code 14 means the heat exchanger got hot enough to blow a thermal fuse, and the cause is almost always scale buildup. Noritz is blunt about this one: the fuse can't be reset, it has to be replaced, and you should never try to bypass it.

What you can check: Nothing. Turn the heater off and call.

When it's a pro call: Always. Replacing the fuse is a two-to-four-hour job, and it has to come with a flush, or the next 14 is on its way.

Codes 16 and 20: Overheating Water

Code 16 means the hot water coming out spiked too hot. Code 20 means the high limit switch tripped. Noritz ties both mostly to scale, and 16 can also come from a gas setting or the wrong gas type.

What you can check: One reset. Unplug the heater, wait 20 seconds, and plug it back in.

When it's a pro call: If either code comes back. Noritz warns that resetting a 20 over and over without fixing the cause likely ends in a code 14, and that's the one you can't reset. Noritz's own guidance is that annual maintenance prevents a 16.

Code 29: Condensate Drain

On condensing Noritz models, 29 means the condensate (the acidic water a high-efficiency heater makes) isn't draining. One exception: on the NRCP982, Noritz's manual uses 29 for an air pressure switch problem instead.

What you can check: Follow the small drain line from the heater. It should slope steadily downhill with no flat runs or sags, and it shouldn't be clogged or frozen. A cold snap is a common culprit in garages and crawl spaces.

When it's a pro call: If the line is clear and 29 comes back, or if you have an NRCP and see it.

Code 71: Gas Valve Circuit

This one surprises people. Noritz says a 71 often comes from the power, not the heater: a battery backup or solar inverter that isn't putting out clean power, or a heater sharing a circuit with something like an old refrigerator.

What you can check: If it's safe to do so, try the heater on a different outlet or circuit, and if it runs on backup power, check that the backup is rated for it.

When it's a pro call: If it keeps coming back on clean power.

C1#: Your Noritz Is Due for a Flush

C1 followed by a number (C11 through C19) is Noritz's scale reminder on its condensing premix models. It means the heat exchanger needs flushing.

Here's what most owners don't know: this reminder is turned off at the factory. The installer or homeowner has to turn it on. So a Noritz that has never shown a C1 code isn't necessarily clean inside. It may just never have been asked to warn you. And Noritz's warranty doesn't cover scale damage, including when a C1 code showed up and the heat exchanger wasn't flushed.

Noritz's manuals just say to flush "periodically." Our recommendation is once a year, whether your home is on city water in Concord, Kannapolis, or Salisbury or on a private well in Rowan or Iredell County.

Want to learn more about your options? Give us a call to chat with a friendly guide.

Icon

(704) 798-2659

Image

Noritz Not Making Hot Water With No Code?

Start simple. Open the hot water tap all the way, because a tankless needs a minimum flow before it fires. Check that the heater has power and that the remote is on. If it's been below freezing, the unit or its lines may be frozen. If only one faucet is slow to get hot and you have a recirculation system, our hot water recirculation guide explains how those work.

Where DIY Stops

A homeowner can safely:

  • Write down the code and reset once by unplugging the heater
  • Confirm the gas valve to the heater is open and the propane tank isn't empty
  • Clear leaves, nests, or snow from the outside vent and intake
  • Check that the condensate drain line is clear, sloped, and not frozen
  • Plug the heater into another outlet for a code 71, and push the remote cord in for a 760

Everything else goes to a licensed plumber: gas pressure, venting repairs, anything behind the cover, and the descaling flush. Noritz's own guidance is to contact a licensed plumbing and heating contractor, and its manuals say service has to be done by a qualified installer, service agency, or gas supplier to keep the warranty.

What About the Warranty?

A few things in Noritz's warranty matter a lot around here:

  • Scale damage isn't covered. That includes damage after a C1 code showed and the heat exchanger wasn't flushed.
  • Untreated or poorly treated well water isn't covered, and neither is water harder than 12 grains per gallon. If your home is on a private well in Rowan or Iredell County, that's worth knowing before something goes wrong.
  • The warranty is for the original buyer. It ends when the home is sold. If you bought your house with a Noritz already installed, there's a good chance your heater has no warranty at all, which makes maintenance even more important.

Warranty lengths vary by model and use, so check the paperwork for yours.

How We Handle Noritz Repairs

When you call us with a Noritz code, the person who diagnoses it is the person who does the work. We read the code, check the gas, venting, condensate line, and the parts behind the cover, and tell you what's wrong and what it costs before any work starts. If a flush is what your heater needs, we'll tell you that, and if the unit is near the end of its life, we'll tell you that plainly too.

Tankless is what we do most. Our owner, Jonathan Johns, holds an NC P1 Unlimited Plumbers License and is a Navien Certified Service Specialist, and we've repaired and maintained more than 300 tankless systems around Cabarrus, Rowan, and Iredell County. We service all the major tankless brands, Noritz included. Our service call is $94, and it's waived when you go ahead with the repair. After-hours visits (after 5 PM on weekdays, and on Saturdays) are $189. Full water heater and tankless pricing is on our pricing page.

Frequently Asked Questions

What does error code 11 mean on a Noritz tankless water heater?

Code 11 is an ignition failure: the heater saw the demand for hot water but couldn't light. Check that the gas valve to the heater is open, that your other gas appliances work, and that a propane tank isn't empty. Then close and reopen the hot water faucet or power the heater off and on. If 11 comes back, call a licensed plumber. Around here, the most common cause we find is a dirty flame rod.

How do I reset my Noritz tankless water heater?

Turn the power off and back on: unplug the heater or switch off its breaker, wait 20 to 30 seconds, and plug it back in. Reset once. Codes 14 and 908 can't be reset this way and need a technician.

What does code 90 mean on a Noritz?

Code 90 is a combustion abnormality: the fuel and air mix is off. Check that the outside vent and air intake are clear and that the condensate line isn't clogged or frozen. Noritz recommends contacting a contractor right away if it comes back, since repeated resets can lock the heater out with a 908.

What does C1 mean on a Noritz tankless?

A C1 code (C11 through C19) is Noritz's scale reminder: the heat exchanger needs flushing. The reminder is turned off at the factory, so a heater that has never shown one may still need a flush. Noritz's warranty doesn't cover scale damage.

How often should a Noritz tankless be flushed?

We recommend once a year, whether your home is on city water or a private well. Don't count on the C1 reminder to tell you: it's turned off at the factory, so many Noritz units never show it.

Is my Noritz still under warranty if I bought the house with it?

Probably not. Noritz's warranty covers the original buyer and ends when the home is sold. It also excludes scale damage and untreated well water, so regular maintenance matters even more on an inherited unit.

The code meanings in this article come from Noritz's owner's manuals and the Noritz Knowledge Base, which has a page for each code. Noritz Technical Support is 866-766-7489.

If your Noritz is showing a code that keeps coming back, or you'd rather not guess, give us a call. We'll tell you straight what the code means on your unit and what it'll take to fix it. You can reach us at (704) 798-2659 or book online. You can also read more about our tankless water heater repair and maintenance service, or see our Navien and Rinnai error code guides.

Jonathan Johns from Macaw Plumbing, kneeling indoors with a dog at his side.

Jonathan Johns

Jonathan Johns is the owner and lead plumber at Macaw Plumbing & Tankless, a family-owned plumbing company serving Salisbury, Mooresville, China Grove, and surrounding communities across Cabarrus, Rowan, and Iredell Counties. He holds NC State License #L.35944 (North Carolina P1 Unlimited Plumbers License) with Well Seal Certification and is a certified Navien Service Specialist.

Get the Plumbing Service Your Home Deserves

Don't wait for a small problem to become a big one. Whether you need an emergency plumber or a long-term upgrade that boosts efficiency and reliability, we're here to help.